Emergency OT Support
Dispatch ready in 33 districts
CDSCO LICENSED
ISO 13485:2016
GMP CERTIFIED
PAN-INDIA MASTER FRANCHISE
SURGICAL SUPPORT CERTIFIED
CDSCO LICENSED
ISO 13485:2016
GMP CERTIFIED
PAN-INDIA MASTER FRANCHISE
SURGICAL SUPPORT CERTIFIED
❤️

MILTONIA

Heart Valves

❤️ CardiovascularREF: MLT-AOR-AP✓ Brochure Verified

MILTONIA Bi-Leaflet Mechanical Heart Valve - Aortic (Advanced Performance)

MILTONIA · Heart Valves

Pyrolytic Carbon Mechanical Aortic Valve Prosthesis with Tungsten Impregnation
MaterialPyrolytic Carbon over Graphite substrate with 12% Tungsten impregnation
WhatsApp Quote
Full Technical Matrix
Full Technical Matrix

MILTONIA Bi-Leaflet Mechanical Heart Valve - Aortic (Advanced Performance)

Technical Blueprint SpecificationClinical Value
opening_angle
85°
tungsten_content
12%
silicon_content
3-8%
mri_conditional
3 Tesla
vertical_leaflet_exposure
8.7-10.9mm

leaflet_material

Pyrolytic Carbon over Graphite substrate

sewing_cuff

Double Velour Polyester fabric - modified for supra-annular seating

stiffening_ring

Titanium

Primary Material

Pyrolytic Carbon over Graphite substrate with 12% Tungsten impregnation

CDSCO Validated Data
Frequently Asked Questions

Pyrolytic Carbon Mechanical Aortic Valve Prosthesis with Tungsten Impregnation

The 85° opening angle is designed to optimize hemodynamics, minimizing pressure gradients and maximizing effective orifice area (EOA) to reduce the risk of patient-prosthesis mismatch and improve long-term clinical outcomes.

The pyrolytic carbon leaflets offer excellent thromboresistance, minimizing the risk of thrombus formation. The addition of 12% tungsten and 3-8% silicon enhances the material's strength, wear resistance, and overall durability, contributing to long-term valve function.

The modified double velour polyester sewing cuff facilitates secure supra-annular seating, simplifying the implantation process. The titanium stiffening ring provides enhanced structural support, preventing paravalvular leakage and ensuring proper valve orientation within the aortic annulus.

This product is manufactured by Meril Life Sciences and is distributed by Agile Healthcare across all districts of Telangana.

Yes, all Meril Life Sciences products distributed by Agile Healthcare, including the MILTONIA Bi-Leaflet Mechanical Heart Valve - Aortic (Advanced Performance), strictly adhere to CDSCO guidelines and ISO 13485:2016 quality standards.

The MILTONIA Bi-Leaflet Mechanical Heart Valve - Aortic (Advanced Performance) is constructed using Pyrolytic Carbon over Graphite substrate with 12% Tungsten impregnation, ensuring high biocompatibility and durability.